- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Bottorff, Brandon (1)
-
Dusanter, Sebastien (1)
-
Mielke, Levi (1)
-
Reidy, Emily (1)
-
Stevens, Philip S. (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
& Abreu-Ramos, E. D. (0)
-
& Adams, S.G. (0)
-
& Ahmed, K. (0)
-
& Ahmed, Khadija. (0)
-
& Aina, D.K. Jr. (0)
-
& Akcil-Okan, O. (0)
-
& Akuom, D. (0)
-
& Aleven, V. (0)
-
& Andrews-Larson, C. (0)
-
& Archibald, J. (0)
-
& Arnett, N. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract. A new instrument for the measurement of atmosphericnitrous acid (HONO) and hydroxyl radicals (OH) has been developed usinglaser photofragmentation (LP) of HONO at 355 nm after expansion into alow-pressure cell, followed by resonant laser-induced fluorescence (LIF) ofthe resulting OH radical fragment at 308 nm similar to the fluorescenceassay by gas expansion technique (FAGE). The LP/LIF instrument is calibratedby determining the photofragmentation efficiency of HONO andcalibrating the instrument sensitivity for detection of the OH fragment. Inthis method, a known concentration of OH from the photo-dissociation ofwater vapor is titrated with nitric oxide to produce a known concentrationof HONO. Measurement of the concentration of the OH radical fragmentrelative to the concentration of HONO provides a measurement of thephotofragmentation efficiency. The LP/LIF instrument has demonstrated a1σ detection limit for HONO of 9 ppt for a 10 min integration time.Ambient measurements of HONO and OH from a forested environment and an urbansetting are presented along with indoor measurements to demonstrate theperformance of the instrument.more » « less
An official website of the United States government
